<![CDATA[HVAC Parts]]> http://www.acunitdirect.com/replacement-parts Sun, 05 Feb 2012 12:51:15 +0000 Zend_Feed http://blogs.law.harvard.edu/tech/rss <![CDATA[Motor Start Capacitor, 220-250 VAC 72-88 MFD]]> http://www.acunitdirect.com/motor-start-capacitor-220-250-volt-uf-72-88.html

Electrolytic Capacitors

AC electrolytic starting capcitors are designed for intermittent duty on single-phase capacitor start AC motors. Will operate properly up to 20 starts of threee-second duration per hour at no more than 66 Hz. Meet "EIA" RS-463- Type 2 standards. Round cases are moisture resistand molded plastic. Dual type terminals for quick connect or solder connections. Induvidually packaged.

 

Features:

  • Hermetically sealed
  • Cases made of phenolic resin
  • Standard dual blade terminals
  • UL listed
  • Small dimensions for easy replacement

Specs:

  • Construction: Sealed Molded Phenolic Resin Case
  • Dia.: (In.) 1 13/16
  • Height: (In.) 3 3/8
  • Hz: 60/50
  • Type: Motor Start Capacitor
  • MFD: Rating 72-88
  • Shape: Round
  • Temp.: Range (C) -40 to 65
  • Terminals: 2-blade Quick-connect Insulated
  • Voltage: 220-250

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$7.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Lennox 93M06 Cranckcase Heater - 70 Watt 240 Volts]]> http://www.acunitdirect.com/lennox-93m06-cranckcase-heater-70-watt-240-volts.html

What is the function of Crankcase heater

To keep the compressor oil warm so that refrigerant does not accumulate in the crankcase.

Where are they use

In places where there's really cold weather and the compressor would not start. Typically this is cased by the outside temperature keeping the pressure too low to engage the low pressure switch.

Installation

The 2 wires of the heater is wired directly to the 230 Volt input side of the contactor from the main power supply, and is always supplying 230 volts of power to the heater. The result is a warmed lower section of the compressor which drives any refrigerant that gathers there back into the system rather than to allow condensation in the crankcase.

Price:$42.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[York Heat Pump Control Board Part S1-03100251700]]> http://www.acunitdirect.com/s1-03100251700-york-heat-pump-board.html

Replacement Info:

NOTE: The following selected parts are warranty and replacement parts for York, Coleman Evcon, Luxaire, Frazier Johnson and Air Pro air conditioning and heating equipment.

For Use With:

B1SP (24-120), B2SP (36-60), B3SP (24-30), E1CH (90-120), E2CP (18-60), E3CP (18-60), E4CP (60), SHP (50-120), Also used on these Models: E2CP18 E2CP60 E2CP036A06B E3CP18 E3CP60 E4CP60 SHP50 SHP120 S1-03100251700

Price:$188.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Bristol Air Conditioning Heat Pump Compressors H22J41BABCA]]> http://www.acunitdirect.com/bristol-air-conditioning-heat-pump-compressors-h22j41babca.html

About This Product

Single-phase and three-phase Designed for drop-in installation in air conditioning and heat pump applications Direct replacements for many Goodman, Evcon and other major OEMs Compressors come with internal high pressure relief valve and internal linebreak motor protection Completely dehydrated, fully oil charged, with mounting hardware Square mounts Start capacitor and relay listed are optional components for hard start applications


Performance

  • Capacity (BTU/HR):  40929 
  • Type:  Reciprocating 
  • Refrigerant:  R-22 
  • Input Voltage (V):  208 
  • Input Voltage (V):  230 
  • No. of Phases:  1 
  • Freq. (Hz.):  60 
  • Run Capacitor (uF/V):  50/370 
  • Start Kit:  SK-B5  
  • Kick Start:  42-KS1  
  • Start Relay P/N:  42-25105-02  
  • Start Capacitor (uF/V):  216-259/330 
  • Start Capacitor Part Number:  43-17075-06  
  • Rated Load Current (A):  17.1 
  • Max. Continuous Current (A):  28.0 
  • Locked Rotor Current (A):  102.0 
  • Crankcase Heater Included?:  Yes 
  • Crankcase Heater Part Number:  44-17402-06  
  • Soundwrap (Brinmar):  68-25217-10  
  • Refrigerant Oil:  Mineral (85-H2301) 
  • Suction Line Location:  2 
  • Suction Line Height (in.):  14 
  • Suction Line Configuration:  Stub Out 
  • Suction Line Size (in.):  3/4 
  • Discharge Line Location:  5 
  • Discharge Line Height (in.):  4-1/8 
  • Discharge Line Configuration:  Up 
  • Discharge Line Size (in.):  1/2 
  • Overall Compressor Height (in.):  15-7/8 
  • Mounting Base Dimensions (in. x in.):  7-1/2 x 7-1/2 

Nomenclature

Price:$495.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Lennox 15M35 Molded Plug Wiring Harness]]> http://www.acunitdirect.com/lennox-15m35-molded-plug-wiring-harness.html

Replacement Info:

NOTE: Part 15M35 replaced 72L40 72L39 72L38 74M97 74M96 53M02 52M18 52M17 25M30 74M9701 74M9601 72L4001 72L3901 72L3801 53M0201 52M1801 52M1701 25M3001 15M350

Used in the following models:

10ACB42 10ACB48 10ACB60 10ACC-018-230 10ACC-024-230 10ACC-036-230C 10ACC-042-230 10ACC-048-230 10ACC-060-230 10HPB18 10HPB24 10HPB30 10HPB36 10HPB42 10HPB48 10HPB60 12ACB24 12ACB30 12ACB36 12ACB42 12ACB48 12ACB60 12HPB24 12HPB30 12HPB36 12HPB42 12HPB48 12HPB60 13ACC-018-230 13ACC-024-230 13ACC-030-230 13ACC-036-230 13ACC-037-230 13ACC-042-230 13ACC-047-230 13ACC-048-230 13ACC-060-230 13ACD-018-230 13ACD-024-230 13ACD-030-230 13ACD-036-230 13ACD-042-230 13ACD-048-230 13ACD-060-230 13ACX-018-230 13ACX-024-230 13ACX-030-230 13ACX-036-230 13ACX-042-230 13ACX-048-230 13ACX-060-230 13CHPA-24-230 13CHPA-30-230 13CHPA-36-230 13CHPXA-24-230 13CHPXA-30-230 13CHPXA-36-230 13HPD-018-230 13HPD-024-230 13HPD-030-230 13HPD-036-230 13HPD-042-230 13HPD-048-230 13HPD-060-230 13HPX-018-230 13HPX-024-230 13HPX-030-230 13HPX-036-230 13HPX-042-230 13HPX-048-230 13HPX-060-230 13HPX-061-230 14ACX-018-230 14ACX-024-230 14ACX-030-230 14ACX-036-230 14ACX-041-230 14ACX-042-230 14ACX-047-230 14ACX-048-230 14ACX-059-230 14ACX-060-230 14HPX-018-230 14HPX-024-230 14HPX-030-230 14HPX-036-230 14HPX-042-230 14HPX-048-230 14HPX-060-230 2AC13B18P 2AC13B24P 2AC13B30P 2AC13B36P 2AC13B42P 2AC13B48P 2AC13B60P 2AC13L18P 2AC13L24P 2AC13L30P 2AC13L36P 2AC13L42P 2AC13L48P 2AC13L60P 2AC14B18P 2AC14B24P 2AC14B30P 2AC14B36P 2AC14B42P 2AC14B48P 2AC14B60P 2AC14BC18P 2AC14BC24P 2AC14BC30P 2AC14BC36P 2AC14L18 2AC14L18P 2AC14L24 2AC14L24P 2AC14L30 2AC14L30P 2AC14L36 2AC14L36P 2AC14L42 2AC14L42P 2AC14L48 2AC14L48P 2AC14L60 2AC14L60P 2AC14LC18P 2AC14LC24P 2AC14LC30P 2AC14LC36P 2HP13B18P 2HP13B24P 2HP13B30P 2HP13B36P 2HP13B36T 2HP13B42P 2HP13B48P 2HP13B48T 2HP13B60P 2HP13B60T 2HP13L18P 2HP13L24P 2HP13L30P 2HP13L36P 2HP13L36T 2HP13L42P 2HP13L48P 2HP13L48T 2HP13L60P 2HP13L60T 2HP14B18P 2HP14B24P 2HP14B30P 2HP14B36P 2HP14B42P 2HP14B48P 2HP14B60P 2HP14L-18 2HP14L-24 2HP14L-30 2HP14L-36 2HP14L-42 2HP14L-48 2HP14L-60 2SH13B24P 2SH13B30P 4AC13B18P 4AC13B24P 4AC13B30P 4AC13B36P 4AC13B42P 4AC13B48P 4AC13B60P 4AC13L18P 4AC13L24P 4AC13L30P 4AC13L36P 4AC13L42P 4AC13L48P 4AC13L60P 4AC14L18P 4AC14L24P 4AC14L30P 4AC14L36P 4AC14L41P 4AC14L42P 4AC14L47P 4AC14L48P 4AC14L60P 4HP13B18P 4HP13B24P 4HP13B30P 4HP13B36P 4HP13B42P 4HP13B48P 4HP13B60P 4HP13L18P 4HP13L24P 4HP13L30P 4HP13L36P 4HP13L42P 4HP13L48P 4HP13L60P 4HP14B18P 4HP14B24P 4HP14B30P 4HP14B42P 4HP14B48P 4HP14B60P 4HP14L18P 4HP14L24P 4HP14L30P 4HP14L36P 4HP14L42P 4HP14L48P 4HP14L60P AC10B24 AC10B30 AC10B36 AC10B42 AC10B48 AC12B30 AC13-018-230 AC13-024-230 AC13-030-230 AC13-036-230 AC13-042-230 AC13-048-230 AC13-060-230 AFAIR10B18 AFAIR10B24 AFAIR10B30-A AFAIR10B36-B AFAIR10B42 AFAIR10B42-A AFAIR10B48 AFAIR10B48-A AFAIR10B60-A AFAIR12B18 AFAIR12B24 AFAIR12B24PA AFAIR12B30-A AFAIR12B36 AFAIR12B36PA AFAIR12B42 AFAIR12B48 AFAIR12B60 AFGP10B24050

Price:$24.95

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Copeland Scroll Compressor 3.5 Ton R22 ZR40K3-PFV-230]]> http://www.acunitdirect.com/copeland-scroll-compressor-3-5-ton-r22-zr40k3-pfv-230.html

Used in the following models:

100GRTC42A,10ACB42,10ACC-042-230,125GRTC42A,12ACB42,12CHP042,12GCS042-100,12GCS042-75,12GCS042X-100,12GCS042X-75,12HPB42,150GRTC42A,2AC14B48P,2AC14L48,2AC14L48P,2HP13B48P,2HP13B48T,2HP13L48P,2HP13L48T,2HP14B48P,2HP14L-48,2HP14L48P,AFAIR12B42,AFGP12B42075,AFGP12B42100,AFHEAT12B42,AFHP12B42,AFSH12B42P,C0AL-42-230,C2AL-42-230,CHP20-042,CHP20R-042,CHP20R-461,CHP20RV-461,CHP26-042,GCS20-042-120,GCS20-042-75,GCS20R-042-120,GCS20R-042-75,HP12B42,HP26-042,HP27-042,HP28-042,HP30-461,HS26-042,HS29-042,HS30-461,LCA042H,LCC042S2,LGA042H,TCA060S2,TGA060S2,TSA060S2

Copeland ZR40K3-PFV-230

Performance

  • HCFC, R-22, 60Hz, 1- Phase, 208/230 V
  • (Capacity : 28500 ~ 33700
  • Current (Amps): 9.0 ~ 6.30
  • EER (Btu/Wh): 11.90 ~ 19.00
  • Mass Flow (lbs/hr): 418 ~ 434
  • Sound Power (dBA): 68 Avg ~ 73 Max
  • Vibration (mils(peak- 2.0 Avg ~ 3.0 Max

Nomenclature

Price:$572.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Compressor Saver Hard Start Capacitor Model CSR U2]]> http://www.acunitdirect.com/compressor-saver-hard-start-capacitor-model-csr-u1-1.html

The 5-2-1 Compressor Saver

Starting up is the hardest time in the life of any type of electrical equipment. Ever notice that light bulbs almost always burn out when you first turn them on and not while they are on? This is due to the huge current that rushes in when a switch is thrown and power is first applied.

 

Your air conditioner uses anywhere from 5 to 10 times more power on start-up than it does while running. With this burst of power comes a surge of heat that accompanies the electrical current. This heat damages the compressor, the terminals, the windings and run capacitor – all vital components of your air conditioner.

 

The 5-2-1 Compressor Saver® protects these components by significantly reducing the amount of time it takes for your compressor to start – in some cases up to 50%. This means your air conditioner and compressor will bear ½ the stress, strain and heat each and every time it starts. Considering that your air conditioner may start up more than 6,000 times in a single cooling season, the positive impact that the 5-2-1 Compressor Saver® has on your air conditioner is significant.

 

Before you replace your air conditioner, try adding a 5-2-1 Compressor Saver®. The 5-2-1 Compressor Saver® might save you from having to outlay thousands of dollars to buy a new air conditioner or compressor. At a fraction of the cost, installing the 5-2-1 Compressor Saver® is a wise investment.

 

Features:

  • Uses Potential Relay
  • Extend the life of your compressor
  • Reduce damaging in-rush current by up to 50%
  • Protect vital internal components
  • Save homeowners from costly repairs
  • Start air conditioners that are close to breaking
  • Approved by Compressor Manufacturers
  • Approved by Equipment Manufacturers

 

Specifications:

  • 3.5 -5 TON A/C units
  • 189 - 227 Mfd
  • 208-240V and up to 330VAC

 

Applications:

  • For single phase electricity only
  • Ideally suited for 1 - 3 TON A/C units
  • Air conditioners and heat pumps

 


 

Techincal Diagram

sell sheetsell sheetsell sheet

1) Disconnect all sources of power to the unit. Note that there may be more than one.
2) Locate and remove the electrical service access door or panel.
3) Mount the 5-2-1 Kit potential relay and start capacitor in a suitable location within the electrical box. The potential relay should be mounted with the mounting tab up. The capacitor should be mounted with the terminals up. Take care to mount the components so that all non-insulated live terminals are at least 1/2" away from all metal or electrical conducting parts or components. Mount in a location that will prevent water from coming in contact with the non-insulated live contacts.

NOTE – The 5-2-1Compressor Saver® has been pre-wired for your convenience. There are only 3 color coded wires which need to be connected. The Black wire will be connected to the Common side of the compressor. The Striped wire will be connected to the Start winding of the compressor and the Red wire will be connected to the Run winding of the compressor.

Remember – 5, 2, 1, = Common, Start, Run. Proceed as follows:

"5" Common - Connect the loose end of the Black wire to T1 of the contactor. Check to see that the Common "C" terminal of the compressor also connects to T1. In most cases you will find a Black wire coming from the Common "C" terminal of the compressor.

"2" Start - Connect the loose end of the Striped wire to the Start winding side of the run capacitor. The Start winding side of the run capacitor is always marked "HERM". The Start winding side of the run capacitor can also be verified by following the yellow or orange or blue wire (in most cases) from the compressor "S" terminal to the Start winding side of the run capacitor.

"1" Run- Connect the loose end of the Red wire to the Run winding side of the compressor. The Run winding is connected to T2 of the contactor as well as the common side of the run capacitor which is usually marked with a "C" or "=". The Run winding can be identified in most cases by a Red wire coming from the R terminal on the compressor. The Red wire from the 5-2-1 start kit is normally connected at the "C" or "=" terminal on the run capacitor, but can also be connected to T2 of the contactor. See the illustration below.

Price:$48.95

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Lennox Control Board 60J00]]> http://www.acunitdirect.com/lennox-control-board-60j00.html

Replaces the following defrost control boards:

68J29, 68J84, 29M02 and 56M37.

This control board features:


Features

  • Five- Minute compressor time delay
  • Pressure switch lockout Circuit
  • Loss of charge / Low pressure switch circuit
  • Field- Selectable compressor delay
  • Field connection terminals for service light

Price:$198.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[To-5 Kickstart Hart Start Device Capacitor 2 Wire Non-Polarized System]]> http://www.acunitdirect.com/kickstart-hart-start-device-capacitor-model-to-5.html

Hard-Start Capacitors

Kickstart® Hard Starts are the only pre-assembled, 2-wire, easy-to-install starting devices that utilize the superior sensing capability of a potential relay in combination with a start capacitor. These devices work on all 1 - 5 HP single-phase 208V, 230V, 265V air conditioning, heat pump and refrigeration compressors - reciprocating, scroll and rotary.

 

Features:

  • Covering applications from 1 to 5 ton units
  • For Single Phase 208V,230V,and 265V HVAC/R Applications (1-5 HP)
  • Component rated life expectancy of 50k cycles
  • Instant Restarts
  • UL/CSA and CE recognized
  • 2 Wire non-polarized system
  • OEM versions available on request

 

Specifications:

  • VAC: 250
  • Capacitance: 189-227 MFD
  • Frequency: 50/60 Hz

 

Applications:

  • 1 – 5 HP single-phase 208V, 230V, 265V air conditioning,
    heat pump, and refrigeration compressors -
    reciprocating, scroll and rotary.

For the TO-5, KS8 and MP1 

Standard
Connection

CSIR Compressor

 

Installation For TO-5, KS8 and MP1

installation instruction standard connection CSIR Compressor

Connect blue wires across run capacitor or "COM" and "HERM" on split capacitor.

OEM CROSS REFERENCE

Carrier
Product # Kickstart® Product #
HC95DA175 KSTS216
HC95DA401 KSTS324
HC95DA670 KSTS216LV
HC95DA700 KSTS238LV
Lennox
Product # Kickstart® Product #
89P36 TO-5
77N48 KS1
Trane
Product # Kickstart® Product #
CPT00697 TO-5
KIT2786 KS1
Coleman/Luxaire/York/Fraser-Johnson
Product # Kickstart® Product #
024-31994-000 TO-5
024-31995-000 KS1
024-32005-000 KS8
17494 KSTS216
17495 KSTS234
17496 KSTS324
Maneurop®
Product # Kickstart® Product #
7305543 7305543
WaterFurnace
Product # Kickstart® Product #
16P502-04 KSTS243
16P502-05 KSTS243LV
Goodman/GMC/Janitrol
Product # Kickstart® Product #
TO-5 TO-5
KS1 KS1
B9459-00 KSTS243
B9459-01 KSTS324
Rheem/Ruud/Weatherking
Product # Kickstart® Product #
42-TO5 TO-5
42-KS1 KS1
42-KS8 KS8

Price:$38.95

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Amana,Goodman Condenser Fan Blade - 0161P00030SA]]> http://www.acunitdirect.com/amana-goodman-condenser-fan-blade-0161p00030sa.html

Used in the following models:

DRY093E25CXXX DRY093E25CXXXAB DRY093E35AXXX DRY093E35AXXXAB DRY093E35CXXX DRY093E35CXXXAB PTC073E00AXXX PTC073E00AXXXAB PTC073E00DHXX PTC073E00DHXXAB PTC073E00HRXX PTC073E00HRXXAB PTC073E00HXXX PTC073E00HXXXAB PTC073E25AXXX PTC073E25AXXXAB PTC073E25CXXX PTC073E25CXXXAB PTC073E25DXXX PTC073E25DXXXAB PTC073E25RXXX PTC073E25RXXXAB PTC073E35AXXX PTC073E35AXXXAB PTC073E35CXXX PTC073E35CXXXAB PTC073E35RXXX PTC073E35RXXXAB PTC093E00AXXX PTC093E00AXXXAB PTC093E00HRXX PTC093E00HRXXAB PTC093E00HXXX PTC093E00HXXXAB PTC093E25AXXX PTC093E25AXXXAB PTC093E25CXXX PTC093E25CXXXAB PTC093E25RXXX PTC093E25RXXXAB PTC093E35AXXX PTC093E35AXXXAB PTC093E35CXXX PTC093E35CXXXAB PTC093E35DXXX PTC093E35DXXXAB PTC093E35RXXX PTC093E35RXXXAB PTC093E50AXXX PTC093E50AXXXAB PTC093E50CXXX PTC093E50CXXXAB PTC093E50RXXX PTC093E50RXXXAB PTC093E50VXXX PTC093E50VXXXAB

Price:$22.95

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Copeland Scroll Compressor 7.5 Ton ZR94KC-TF5-250]]> http://www.acunitdirect.com/copeland-scroll-compressor-7-5-ton-zr94kc-tf5-250.html

Copeland 7-1/2 HP, 200-230V, 3 PH, 94,000 BTU, R22, Scroll Compressor Replacement

Specs

  • Model: ZR94KC-TF5-250
  • Manufactured by: Copeland

Price:$1,540.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Lennox Fan Assembly, 4 Blade, 18" Diameter 1/2" Bore 98M20]]> http://www.acunitdirect.com/lennox-fan-assembly-4-blade-18-diameter-1-2-bore-98m20.html

Replacement Info:

NOTE: Part 98M20 replaced 100060-09 68J2801

Used in the following models:

10ACB48 10ACB60 10ACC-036-230C 10ACC-042-230 10ACC-048-230 10ACE-048-230 10ACE-060-230 10HPB48 10HPB60 12ACB42 12HPB42 13ACC-042-230 13ACD-042-230 13ACX-018-230 13ACX-024-230 13ACX-042-230 2SCU13LE142P AC13-042-230 AFHP10B42 AFSH10B42 C0AL-48-230 C2AL-42-230 HP29-042 HP29-048 HP29-060 HP29-511 HP29-513 HP29-651 HP29-653 HP29A-048 HP30-461 HP40-048 HPXA12-042-230 HS29-048 HS29-048S HS29-060 HS29-062 HS29-062S HS29-511 HS29-513 HS29-651 HS29-653 HS29A-048 HS29A-060 HS30-461 HS40-048 HSXA12-042-230 HSXA12-048-230 HSXA12-048-233 HSXA12-048-463

Price:$65.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Copeland Scroll Compressor 5 Ton R22 ZR61K3-PFV]]> http://www.acunitdirect.com/copeland-scroll-compressor-5-ton-r22-zr61k3-pfv.html

Specs:

  • Capacity (BTU/HR): 62000
  • Type: Scroll
  • Refrigerant: R-22
  • Input Voltage (V): 208
  • Input Voltage (V): 230
  • No. of Phases: 1
  • Freq. (Hz.): 60
  • Run Capacitor (uF/V): 80/370
  • Start Kit: SK-A4
  • Kick Start: 42-KS1
  • Start Relay P/N: 42-25105-01
  • Start Capacitor (uF/V): 270-324/330
  • Start Capacitor Part Number: 43-17075-07
  • Rated Load Current (A): 32.1
  • Max. Continuous Current (A): 45
  • Locked Rotor Current (A): 148
  • Crankcase Heater Included?: No
  • Crankcase Heater Part Number:44-17402-47
  • Soundwrap (Brinmar): 68-25217-10
  • Refrigerant Oil: Mineral (85-H2301)
  • Suction Line Location: 2
  • Suction Line Height (in.): 11-5/8
  • Suction Line Configuration: Stub Out
  • Suction Line Size (in.): 7/8
  • Discharge Line Location: 3
  • Discharge Line Height (in.): 16-1/8
  • Discharge Line Configuration: Stub Out
  • Discharge Line Size (in.): 1/2
  • Overall Compressor Height (in.): 17-3/8
  • Mounting Base Dimensions (in. x in.): 7-1/2 x 7-1/2

Nomenclature

Price:$720.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Compressor Saver Hard Start Capacitor Model CSR U3]]> http://www.acunitdirect.com/compressor-saver-hard-start-capacitor-model-csr-u3.html

The 5-2-1 Compressor Saver

Starting up is the hardest time in the life of any type of electrical equipment. Ever notice that light bulbs almost always burn out when you first turn them on and not while they are on? This is due to the huge current that rushes in when a switch is thrown and power is first applied.

 

Your air conditioner uses anywhere from 5 to 10 times more power on start-up than it does while running. With this burst of power comes a surge of heat that accompanies the electrical current. This heat damages the compressor, the terminals, the windings and run capacitor – all vital components of your air conditioner.

 

The 5-2-1 Compressor Saver® protects these components by significantly reducing the amount of time it takes for your compressor to start – in some cases up to 50%. This means your air conditioner and compressor will bear ½ the stress, strain and heat each and every time it starts. Considering that your air conditioner may start up more than 6,000 times in a single cooling season, the positive impact that the 5-2-1 Compressor Saver® has on your air conditioner is significant.

 

Before you replace your air conditioner, try adding a 5-2-1 Compressor Saver®. The 5-2-1 Compressor Saver® might save you from having to outlay thousands of dollars to buy a new air conditioner or compressor. At a fraction of the cost, installing the 5-2-1 Compressor Saver® is a wise investment.

 

Features:

  • Uses Potential Relay
  • Extend the life of your compressor
  • Reduce damaging in-rush current by up to 50%
  • Protect vital internal components
  • Save homeowners from costly repairs
  • Start air conditioners that are close to breaking
  • Approved by Compressor Manufacturers
  • Approved by Equipment Manufacturers

 

Specifications:

  • 4 -5 TON A/C units
  • 189 - 227 Mfd
  • 270-324V and up to 330VAC

 

Applications:

  • For single phase electricity only
  • Ideally suited for 1 - 3 TON A/C units
  • Air conditioners and heat pumps

 


 

Techincal Diagram

sell sheetsell sheetsell sheet

1) Disconnect all sources of power to the unit. Note that there may be more than one.
2) Locate and remove the electrical service access door or panel.
3) Mount the 5-2-1 Kit potential relay and start capacitor in a suitable location within the electrical box. The potential relay should be mounted with the mounting tab up. The capacitor should be mounted with the terminals up. Take care to mount the components so that all non-insulated live terminals are at least 1/2" away from all metal or electrical conducting parts or components. Mount in a location that will prevent water from coming in contact with the non-insulated live contacts.

NOTE – The 5-2-1Compressor Saver® has been pre-wired for your convenience. There are only 3 color coded wires which need to be connected. The Black wire will be connected to the Common side of the compressor. The Striped wire will be connected to the Start winding of the compressor and the Red wire will be connected to the Run winding of the compressor.

Remember – 5, 2, 1, = Common, Start, Run. Proceed as follows:

"5" Common - Connect the loose end of the Black wire to T1 of the contactor. Check to see that the Common "C" terminal of the compressor also connects to T1. In most cases you will find a Black wire coming from the Common "C" terminal of the compressor.

"2" Start - Connect the loose end of the Striped wire to the Start winding side of the run capacitor. The Start winding side of the run capacitor is always marked "HERM". The Start winding side of the run capacitor can also be verified by following the yellow or orange or blue wire (in most cases) from the compressor "S" terminal to the Start winding side of the run capacitor.

"1" Run- Connect the loose end of the Red wire to the Run winding side of the compressor. The Run winding is connected to T2 of the contactor as well as the common side of the run capacitor which is usually marked with a "C" or "=". The Run winding can be identified in most cases by a Red wire coming from the R terminal on the compressor. The Red wire from the 5-2-1 start kit is normally connected at the "C" or "=" terminal on the run capacitor, but can also be connected to T2 of the contactor. See the illustration below.

Price:$48.95

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Condenser Fan Motor 1/6HP 208/230V 1075 RPM]]> http://www.acunitdirect.com/condenser-fan-motor-1-6hp-208-230v-1075-rpm.html
Product Details

 
Part No.:  1859E 
Horsepower: 1/6 
Voltage: 208-230/1 
Amps: 1.0 
RPM: 1075 
Rotation Type: REV 
Number of Speeds:
Case Length (In.): 3.8 
Shaft Diameter (In.): 1/2 
Shaft Length 1 (In.):
Capacitor: 5µf, 370V 
Ambient (¬∞C): 60 
Bearing: Sleeve 
Enclosure: Totally Enclosed Air Over 
Motor Diameter (In.): 5 5/8 
NEMA Frame: 48Y 
Overall Length (In.): 9.4 
ProductLink: true 
Service Factor: 1.0 
Shipping Weight (Lbs.): 11 
Type: Permanent Split Capacitor 
Vendor: Emerson Specialty Motors 
Web Description: Condenser fan duty motor, PSC, totally enclosed, sleeve bearing, 5 5/8" diameter, 1/6 HP, 208-230 volt, 1075 RPM, REV, 1/2" shaft diameter 
Weight (Lbs.): 11 

Price:$84.13

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Copeland Scroll Compressor 2 Ton R22 ZR22K3-PFV]]> http://www.acunitdirect.com/copeland-scroll-compressor-2-ton-r22-zr22k3-pfv.html

ZR22K3-PFV Air Conditioning


Performance

  • HCFC, R-22, 60Hz, 1- Phase, 208/230 V
  • (Capacity : 22400 ~ 26500
  • Current (Amps): 9.0 ~ 6.30
  • EER (Btu/Wh): 10.70 ~ 18.50
  • Mass Flow (lbs/hr): 328 ~ 341
  • Sound Power (dBA): 68 Avg ~ 73 Max
  • Vibration (mils(peak- 2.0 Avg ~ 3.0 Max

Nomenclature

Price:$465.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[2.5 To 3 Ton TXV Kit - For R410a Refrigerant Equipment]]> http://www.acunitdirect.com/2-5-to-3-ton-txv-kit-for-r410a-refrigerant-equipment-1.html

TX3N4 - 2.5 To 3 Ton TXV Kit - For R410a Refrigerant Equipment

Thermostatic Expansion Valves can be mounted in any position on the evaporator coil inlet and are reliable, efficient and virtually trouble-free. Select the TXV to correspond with the tonnage of your air conditioner or heat pump, as well as to match the type of refrigerant your systems uses, R22 or R410A. They are required for 14 SEER or higher split system heat pumps, and an optional upgrade for other air conditioning systems.


According to a california Energy Commision report, intalling TXV's in all systems would increase the seosonal efficiency 11%.  

 

TXV Manual

Goodman TXV Installation Instructions.pdf 

Price:$2.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Motor Start Capacitor, 125 VAC 1000–1200 MFD]]> http://www.acunitdirect.com/motor-start-capacitor-125-volt-uf-1000-1200.html

Electrolytic Capacitors

AC electrolytic starting capcitors are designed for intermittent duty on single-phase capacitor start AC motors. Will operate properly up to 20 starts of threee-second duration per hour at no more than 66 Hz. Meet "EIA" RS-463- Type 2 standards. Round cases are moisture resistand molded plastic. Dual type terminals for quick connect or solder connections. Induvidually packaged.

 

Features:

  • Hermetically sealed
  • Cases made of phenolic resin
  • Standard dual blade terminals
  • UL listed
  • Small dimensions for easy replacement

Specs:

  • Construction: Sealed Molded Phenolic Resin Case
  • Dia.: (In.) 1 13/16
  • Height: (In.) 4 3/8
  • Hz: 60/50
  • Type: Motor Start Capacitor
  • MFD: Rating 1000–1200
  • Shape: Round
  • Temp.: Range (C) -40 to 65
  • Terminals: 2-blade Quick-connect Insulated
  • Voltage: 110-125

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$15.42

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Copeland Scroll Compressor 1.5 Ton R22 ZR16KA-PFV]]> http://www.acunitdirect.com/copeland-scroll-compressor-zr16ka-pfv-1-5-ton.html

ZR16KA-PFV A/C Only


Performance

  • HCFC, R-22, 60Hz, 1- Phase, 208/230 V
  • (Capacity : 15500 ~ 18300
  • Current (Amps): 6.70 ~ 4.70
  • EER (Btu/Wh): 10.60 ~ 18.50
  • Mass Flow (lbs/hr): 227 ~ 235
  • Sound Power (dBA): 68 Avg ~ 73 Max
  • Vibration (mils(peak- 2.0 Avg ~ 3.0 Max

Nomenclature

Price:$395.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Copeland Scroll Compressor 1.5 Ton R22 ZR16K4-PFV]]> http://www.acunitdirect.com/copeland-scroll-compressor-zr16k4-pfv-1-5-ton.html

ZR16K4-PFV Air Conditioning


Performance

  • HCFC, R-22, 60Hz, 1- Phase, 208/230 V
  • (Capacity : 16500 ~ 19500
  • Current (Amps): 6.70 ~ 4.70
  • EER (Btu/Wh): 10.60 ~ 18.40
  • Mass Flow (lbs/hr): 242 ~ 251
  • Sound Power (dBA): 68 Avg ~ 73 Max
  • Vibration (mils(peak- 2.0 Avg ~ 3.0 Max

Nomenclature

Price:$395.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Copeland Scroll Compressor 2.5 Ton R22 ZR28K3-PFV]]> http://www.acunitdirect.com/copeland-scroll-compressor-2-5-ton-r22-zr28k3-pfv.html

ZR28K3-PFV Air Conditioning


Performance

  • HCFC, R-22, 60Hz, 1- Phase, 208/230 V
  • (Capacity : 28500 ~ 33700
  • Current (Amps): 9.0 ~ 6.30
  • EER (Btu/Wh): 11.90 ~ 19.00
  • Mass Flow (lbs/hr): 418 ~ 434
  • Sound Power (dBA): 68 Avg ~ 73 Max
  • Vibration (mils(peak- 2.0 Avg ~ 3.0 Max

Nomenclature

Price:$545.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Copeland Scroll Compressor 5 Ton R22 ZR40K3-PFV-230]]> http://www.acunitdirect.com/copeland-scroll-compressor-5-ton-r22-zr40k3-pfv-230.html

ZR61K3-PFV-230 Air Conditioning


Performance

  • HCFC, R-22, 60Hz, 1- Phase, 208/230 V
  • (Capacity : 28500 ~ 33700
  • Current (Amps): 9.0 ~ 6.30
  • EER (Btu/Wh): 11.90 ~ 19.00
  • Mass Flow (lbs/hr): 418 ~ 434
  • Sound Power (dBA): 68 Avg ~ 73 Max
  • Vibration (mils(peak- 2.0 Avg ~ 3.0 Max

Nomenclature

Price:$685.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Intellicon - AC Economizer]]> http://www.acunitdirect.com/intellicon-ac-economizer.html

Intellidyne’s IntelliCon® -AC typically reduces home Central Air Conditioning electric consumption by 10% to 20% or more. The IntelliCon-AC is a microprocessorbased, UL listed, electronic control that uses intelligent Dynamic Cycle Management (DCM) technology to automatically adjust the compressor cycles to achieve the greatest efficiency and reduced electrical usage, while assuring consistent temperature levels for even the most temperature sensitive homes. IntelliCon-AC is maintenance free, easy to install by a qualified installer, and is guaranteed to save energy.

Features:

  • Dynamic Cycle Management (DCM) technology reduces air conditioning electric consumption—typically 10% to 20%
  • UL listed, “Energy Management Equipment”
  • Increased savings without replacing or upgrading costly system components
  • “State-of-the-art” microprocessor-based control—LED indicators show operating modes
  • For systems up to 5 tons
  • Protects compressor against momentary power outages and short cycling
  • Simple installation by a qualified HVAC/R installer
  • No programming or follow-up visits required
  • Maximum year-round efficiency
  • Reduces maintenance and extends compressor life
  • Fail-safe operation
  • Guaranteed to save energy
  • 15-year replacement warranty for breakdowns or defects

Overview

Sizing of air conditioning systems is based upon a number of factors. When any of the design considerations are not met, the air conditioning system can become relatively oversized for the cooling load and thus less efficient.

 

IntelliCon-AC works in conjunction with the existing thermostat and will not void the compressor manufacturer’s warranty. An additional feature of the IntelliCon-AC is the accepted industry practice of compressor anti-short-cycling control.

Price:$189.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Goliath Drain Pan, secondary, 30" x 50" With Fittings]]> http://www.acunitdirect.com/goliath-drain-pan-secondary-30-x-50-with-fittings.html

Goliath drain pan, secondary, 30" x 50"


The Goliath, true to its name, is the strongest, most rugged HVAC secondary pan on the market. The Goliath 30"x50" secondary drain pan is designed for horizontal installation and includes the AG-4200 float switch system as well as 14 VI-4200 vibration isolators that reduce vibration noise and friction from air-handlers or furnaces. Pans meet or exceed all international product building codes and are UL approved. DexElar® material is UL-94 5VA and ASTM E-84-05 compliant. 10 year limited warranty.


Product Features:

  • 275° temperature rating
  • Includes 16 VI-4200 vibration isolators with AG-4200 float switch
  • Reinforced corners for strength
  • Meets ASTM-E-84-05 and complies with UL -94 5VA
  • Adjustable float sensitivity
  • Residential and commercial use
  • 5 amp high-capacity float switch with integrated drain housing

Price:$68.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Round Motor Run Capacitor, 440 VAC 80+5 MFD]]> http://www.acunitdirect.com/dual-round-motor-run-capacitor-440-vac-80-5-mfd.html

Dual Round Oil-Filled Motor Run Capacitors 440-VAC

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Motors, Air Conditioners and Refrigerators

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Non-PCB dielectric fluid
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 440
  • MFD: Rating 20+5
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Round
  • Can Diam..: (In.) 2
  • Height: (In.) 4 3/4
  • Temp.: Range (C) -40 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$31.85

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Lennox Control Board 34M63]]> http://www.acunitdirect.com/lennox-control-board-34m63.html

Replaces the following defrost control boards:

68J29, 68J84, 29M02 and 56M37.

This control board features:


Features

  • Five- Minute compressor time delay
  • Pressure switch lockout Circuit
  • Loss of charge / Low pressure switch circuit
  • Field- Selectable compressor delay
  • Field connection terminals for service light

Price:$116.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Drain pan, secondary, 26" x 26" ]]> http://www.acunitdirect.com/drain-pan-secondary-26-x-26.html

Drain pan, secondary, 26" x 26"

  • Rolled edges for durability
  • Ribbed bottoms for rigidity
  • Reinforced corners for strength
  • 3/4" PVC fittings attached to each pan
  • No seams—no rust—no leakage
  • Depth 2"; Overall dimension + 2"
  • S suffix = Drain line outlets in short side
  • L suffix = Drain line outlets in long side

Price:$22.95

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Trane IC ICM316C Heat Pump Defrost Timer]]> http://www.acunitdirect.com/trane-ic-icm316c-defrost-timer-with-solid-state-reliability.html

ICM316 Trane Heat Pump Defrost Timer

The ICM316C provides a selectable time interval between defrost cycles. It will allow a 10 minute defrost every 30/60/90 minutes as long as the DFT is closed on the SEN terminal. A HOLD input allows the timer to accumulate time while the compressor is running.

A warm coil causes the DFT to open which will prevent time accumulation or end the defrost period. When the defrost period ends, either by opening the DFT or after the 10 minute defrost period has elapsed, the timer is reset.


Each defrost control is shipped with detailed instructions.


Features:

  • Ultra low cost
  • Pin-for-pin compatible with Nordyne controls
  • Simple time and temperature control
  • Must have external relays for fan, reversing valve and auxiliary heat
  • High installed base

Price:$62.85

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[IC ICM301C Defrost Control - Rheem Ruud Heat Pump]]> http://www.acunitdirect.com/ic-icm301c-defrost-control-rheem-ruud-heat-pump.html

ICM301 Heat Pump Defrost Timer For Rheem | Ruud

The ICM301 provides a selectable time interval between defrost cycles. It will allow a 10 minute defrost every 30/60/90 minutes as long as the DFT is closed on the SEN terminal. A HOLD input allows the timer to accumulate time while the compressor is running.

A warm coil causes the DFT to open which will prevent time accumulation or end the defrost period. When the defrost period ends, either by opening the DFT or after the 10 minute defrost period has elapsed, the timer is reset.


Each defrost control is shipped with detailed instructions.


Features:

  • Ultra low cost
  • Pin-for-pin compatible with Rheem or Ruud controls
  • Simple time and temperature control
  • Must have external relays for fan, reversing valve and auxiliary heat
  • High installed base

Price:$34.29

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[IC ICM302C Defrost Control - Nordyne Heat Pump]]> http://www.acunitdirect.com/ic-icm302c-defrost-control-nordyne-heat-pump.html

ICM302 Heat Pump Defrost Timer

The ICM302 provides a selectable time interval between defrost cycles. It will allow a 10 minute defrost every 30/60/90 minutes as long as the DFT is closed on the SEN terminal. A HOLD input allows the timer to accumulate time while the compressor is running.

A warm coil causes the DFT to open which will prevent time accumulation or end the defrost period. When the defrost period ends, either by opening the DFT or after the 10 minute defrost period has elapsed, the timer is reset.


Each defrost control is shipped with detailed instructions.


Features:

  • Ultra low cost
  • Pin-for-pin compatible with Nordyne controls
  • Simple time and temperature control
  • Must have external relays for fan, reversing valve and auxiliary heat
  • High installed base

Price:$52.15

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[IC ICM300C Defrost Control - OEM Type 621 Heat Pump]]> http://www.acunitdirect.com/ic-icm300c-defrost-control-oem-type-621.html

ICM300 Heat Pump Defrost Timer

The ICM300 provides a selectable time interval between defrost cycles. It will allow a 10 minute defrost every 30/60/90 minutes as long as the DFT is closed on the SEN terminal. A HOLD input allows the timer to accumulate time while the compressor is running.

A warm coil causes the DFT to open which will prevent time accumulation or end the defrost period. When the defrost period ends, either by opening the DFT or after the 10 minute defrost period has elapsed, the timer is reset.


Each defrost control is shipped with detailed instructions.


Features:

  • Ultra low cost
  • Pin-for-pin compatible with OEM type 621 controls
  • Simple time and temperature control
  • Must have external relays for fan, reversing valve and auxiliary heat
  • High installed base

Price:$29.62

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Motor Run Capacitor, 440 Volts 40 MFD]]> http://www.acunitdirect.com/motor-run-capacitor-440-volts-40-mfd.html

Oval Oil-Filled Motor Run Capacitors

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Motors, Air Conditioners and Refrigerators

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 440
  • MFD: Rating 40
  • Hz: 60/50
  • Type: Motor Run
  • Shape: Round
  • Width.: (In.) 1 5/16
  • Height: (In.) 2 5/8
  • Depth: (In.) 2 5/32
  • Temp.: Range (C) -40 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$8.85

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Bristol Compressor 3 Ton R22 H23A383ABCA]]> http://www.acunitdirect.com/bristol-compressor-3-ton-r22-h23a383abca.html

ZR28K3-PFV Air Conditioning


Performance

  • HCFC, R-22, 60Hz, 1- Phase, 208/230 V
  • (Capacity : 28500 ~ 33700
  • Current (Amps): 9.0 ~ 6.30
  • EER (Btu/Wh): 11.90 ~ 19.00
  • Mass Flow (lbs/hr): 418 ~ 434
  • Sound Power (dBA): 68 Avg ~ 73 Max
  • Vibration (mils(peak- 2.0 Avg ~ 3.0 Max

Nomenclature

Price:$610.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Compressor Saver CSR U1 Hard Start Capacitor]]> http://www.acunitdirect.com/compressor-saver-hard-start-capacitor-model-csr-u1.html

The 5-2-1 Compressor Saver

Starting up is the hardest time in the life of any type of electrical equipment. Ever notice that light bulbs almost always burn out when you first turn them on and not while they are on? This is due to the huge current that rushes in when a switch is thrown and power is first applied.

 

Your air conditioner uses anywhere from 5 to 10 times more power on start-up than it does while running. With this burst of power comes a surge of heat that accompanies the electrical current. This heat damages the compressor, the terminals, the windings and run capacitor – all vital components of your air conditioner.

 

The 5-2-1 Compressor Saver® protects these components by significantly reducing the amount of time it takes for your compressor to start – in some cases up to 50%. This means your air conditioner and compressor will bear ½ the stress, strain and heat each and every time it starts. Considering that your air conditioner may start up more than 6,000 times in a single cooling season, the positive impact that the 5-2-1 Compressor Saver® has on your air conditioner is significant.

 

Before you replace your air conditioner, try adding a 5-2-1 Compressor Saver®. The 5-2-1 Compressor Saver® might save you from having to outlay thousands of dollars to buy a new air conditioner or compressor. At a fraction of the cost, installing the 5-2-1 Compressor Saver® is a wise investment.

 

Features:

  • Uses Potential Relay
  • Extend the life of your compressor
  • Reduce damaging in-rush current by up to 50%
  • Protect vital internal components
  • Save homeowners from costly repairs
  • Start air conditioners that are close to breaking
  • Approved by Compressor Manufacturers
  • Approved by Equipment Manufacturers

 

Specifications:

  • 1 - 3 TON A/C units
  • 88 - 108 Mfd
  • 208-240V and up to 330VAC

 

Applications:

  • For single phase electricity only
  • Ideally suited for 1 - 3 TON A/C units
  • Air conditioners and heat pumps

 


 

Techincal Diagram

sell sheetsell sheetsell sheet

1) Disconnect all sources of power to the unit. Note that there may be more than one.
2) Locate and remove the electrical service access door or panel.
3) Mount the 5-2-1 Kit potential relay and start capacitor in a suitable location within the electrical box. The potential relay should be mounted with the mounting tab up. The capacitor should be mounted with the terminals up. Take care to mount the components so that all non-insulated live terminals are at least 1/2" away from all metal or electrical conducting parts or components. Mount in a location that will prevent water from coming in contact with the non-insulated live contacts.

NOTE – The 5-2-1Compressor Saver® has been pre-wired for your convenience. There are only 3 color coded wires which need to be connected. The Black wire will be connected to the Common side of the compressor. The Striped wire will be connected to the Start winding of the compressor and the Red wire will be connected to the Run winding of the compressor.

Remember – 5, 2, 1, = Common, Start, Run. Proceed as follows:

"5" Common - Connect the loose end of the Black wire to T1 of the contactor. Check to see that the Common "C" terminal of the compressor also connects to T1. In most cases you will find a Black wire coming from the Common "C" terminal of the compressor.

"2" Start - Connect the loose end of the Striped wire to the Start winding side of the run capacitor. The Start winding side of the run capacitor is always marked "HERM". The Start winding side of the run capacitor can also be verified by following the yellow or orange or blue wire (in most cases) from the compressor "S" terminal to the Start winding side of the run capacitor.

"1" Run- Connect the loose end of the Red wire to the Run winding side of the compressor. The Run winding is connected to T2 of the contactor as well as the common side of the run capacitor which is usually marked with a "C" or "=". The Run winding can be identified in most cases by a Red wire coming from the R terminal on the compressor. The Red wire from the 5-2-1 start kit is normally connected at the "C" or "=" terminal on the run capacitor, but can also be connected to T2 of the contactor. See the illustration below.

Price:$37.95

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Goodman Electronic All Fuel Control Board Kit]]> http://www.acunitdirect.com/goodman-electronic-all-fuel-control-board-kit.html

The AFE18 control is designed for use in heat pump applications where the indoor coil is located above/ downstream of a gas or fossil fuel furnace. It will operate with single and two stage heat pumps and single and two stage furnaces. The AFE18 control will turn the heat pump unit off when the furnace is turned on. An anti-short cycle feature is also incorporated which initiates a 3 minute timed off delay when the compressor goes off. On initial power up or loss and restoration of power, this 3 minute timed off delay will be initiated. The compressor won’t be allowed to restart until the 3 minute off delay has expired. Also included is a 5 second de-bounce feature on the “Y, E, W1 and O” thermostat inputs. These thermostat inputs must be present for 5 seconds before the AFE18 control will respond to it.

 

An optional outdoor thermostat, OT18-60A, can be used with the AFE18 to switch from heat pump operation to furnace operation below a specific ambient temperature setting, i.e. breakeven temperature during heating. When used in this manner, the “Y” heat demand is switched to the “W1” input to the furnace by the outdoor thermostat and the furnace is used to satisfy the first stage “Y” heat demand. On some controls, if the outdoor thermostat fails closed in this position during the heating season, it will turn on the furnace during the cooling season on a “Y” cooling demand. In this situation, the furnace produces heat and increases the indoor temperature thereby never satisfying the cooling demand. The furnace will continue to operate and can only be stopped by switching the thermostat to the off position or removing power to the unit and then replacing the outdoor thermostat. When the AFE18 receives a “Y” and “O” input from the indoor thermostat, it recognizes this as a cooling demand in the cooling mode. If the outdoor thermostat is stuck in the closed position switching the “Y” demand to the “W1” furnace input during the cooling mode as described above, the AFE18 won’t allow the furnace to operate. The outdoor thermostat will have to be replaced to restore the unit to normal operation.

Price:$72.00

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Motor Run Capacitor, 440 Volts 5 MFD]]> http://www.acunitdirect.com/motor-run-capacitor-440-volts-5-mfd.html

Oval Oil-Filled Motor Run Capacitors

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Motors, Air Conditioners and Refrigerators

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 440
  • MFD: Rating 5
  • Hz: 60/50
  • Type: Motor Run
  • Shape: Round
  • Width.: (In.) 1 5/16
  • Height: (In.) 2 5/8
  • Depth: (In.) 2 5/32
  • Temp.: Range (C) -40 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$7.35

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 55+5 MFD]]> http://www.acunitdirect.com/dual-motor-run-capacitor-370-volts-55-5-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 55+5
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 3/4
  • Depth.: (In.) 2 3/4
  • Height.: (In.) 4 3/4
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$24.87

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 40+5 MFD]]> http://www.acunitdirect.com/dual-motor-run-capacitor-370-volts-40-5-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 40+5
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$21.42

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 35+4 MFD]]> http://www.acunitdirect.com/dual-rated-oval-motor-run-capacitor-370-vac-35-4-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 35+4
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$21.23

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 35+3 MFD]]> http://www.acunitdirect.com/dual-rated-oval-motor-run-capacitor-370-vac-35-3-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 35+3
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$17.98

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 30+3 MFD]]> http://www.acunitdirect.com/dual-rated-oval-motor-run-capacitor-370-vac-30-3-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 30+3
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$22.19

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 25+10 MFD]]> http://www.acunitdirect.com/dual-rated-oval-motor-run-capacitor-370-vac-25-10-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 25+10
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$21.11

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 25+4 MFD]]> http://www.acunitdirect.com/dual-rated-oval-motor-run-capacitor-370-vac-25-4-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 25+4
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$20.26

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 25+3 MFD]]> http://www.acunitdirect.com/dual-rated-oval-motor-run-capacitor-370-vac-25-3-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 25+3
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$19.22

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 20+4 MFD]]> http://www.acunitdirect.com/dual-rated-oval-motor-run-capacitor-370-vac-20-4-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 20+4
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$18.12

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 17.5+4 MFD]]> http://www.acunitdirect.com/dual-rated-oval-motor-run-capacitor-370-vac-17-5-4-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 17.5+4
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$17.52

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 15+10 MFD]]> http://www.acunitdirect.com/dual-motor-run-capacitor-370-volts-15-10-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 15+10
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$17.42

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 15+5 MFD]]> http://www.acunitdirect.com/dual-motor-run-capacitor-370-volts-15-5-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 15+5
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$17.25

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 15+4 MFD]]> http://www.acunitdirect.com/dual-motor-run-capacitor-370-volts-15-4-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 15+4
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$16.52

]]>
Sun, 05 Feb 2012 12:51:15 +0000
<![CDATA[Dual Rated Oval Motor Run Capacitor, 370-VAC 15+3 MFD]]> http://www.acunitdirect.com/dual-motor-run-capacitor-370-volts-15-3-mfd.html

Dual Rated Oil-Filled Motor Run Capacitor

Non-PCB dielectric fluid. Pressure-activated circuit interrupter virtually eliminates case rupture at end of life. For continuous heavy duty application such as air conditioning, refrigeration, business machines, fans, light, ballasts, etc. Seamless steel cases. 1/4", four blade quick disconnect terminal with phenolic insulated caps. Dimensions may vary due to manufacturing changes. Dimensions shown are for reference only.

 

Design For:

Continuous heavy-duty application such as Air Conditioners, Refrigeration, business machines and fans

 

Features:

  • Hermetically Sealed
  • Hermetically Sealed Aluminum Case
  • Phenolic Insulating Bushing
  • UL listed
  • Small Dimensions For Easy Deplacement

Specs:

  • Construction: Hermetically Sealed Aluminum Case
  • Voltage: 370
  • MFD: Rating 15+3
  • Hz: 60/50
  • Type: Dual Rated Motor Run
  • Shape: Oval
  • Width: (In.) 1 29/32
  • Depth.: (In.) 2 29/32
  • Height.: (In.) 2 5/8
  • Temp.: Range (C) -45 to 65
  • Terminals: 1/4" four-blade quick discounnect with phenolic insulated caps

 

MOUNTING:

 

Vertical mounting of the capacitor with the terminals up is recommended. However, horizontal mounting is acceptable providing the vent is located in the up position. Vertical mounting with the terminals down is not recommended because the capacitor life may be reduced and the operation of the pressure relief vent impaired.

 

SAFETY:

 

Because the watt–second value of these capacitors is high, precautions should be taken during the testing of these devices. Discharge resistors should be specified when there is a possibility of a residual charge left on the capacitor or to protect contacts. Mis–application, such as exceeding design limits or applying continuous AC voltage, may result in destruction or explosion of capacitors.

Price:$16.25

]]>