GSX13 Condenser Product Details:

The Goodman® GSX13 uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry. R-410A is chlorine-free to help prevent damage to the ozone layer. With its 13 SEER rating, the GSX13 will help reduce energy consumption throughout the life of the system.

This unit can give you up to a 14 SEER, when matched with a variable speed furnace or variable speed air handler. A 14 SEER system will save approximately 7% - 8% more than a 13 SEER system.  


AEPF Air Handler Product Details:

The Goodman AEPF Multi-Position Air Handler is suitable for use with refrigerants R-410A and R-22. This unit features a check flowrater expansion device (Fixed Orifice) and may be installed in a variety of locations. This air handler operates with an air conditioner or heat pump. This air handler is shipped with the correct orifice (Flowrater) for this listed match. Instead of a Flowrater a Thermostatic Expansion Valve (TXV) can be used. To find out about the benefits of a Thermostatic Expansion Valve. Click here to learn. A heater coil can be added to this Air Handler to provide winter-time heating capabilities. This accessory is not required for standard operation it provides additional convenience if desired.


A federal energy tax credit of up to $1,500 is available on selected products, if placed in service from January 1st, 2010 to December 31st, 2009. To learn more Click here.


GSX13 (outdoor) Condenser Features:

  • AHRI Certified; ETL Listed
  • High-efficiency scroll compressor
  • High pressure switch
  • Pre-charged refrigerant for 15' of line
  • R-410A chlorine-free, environmentally friendly refrigerant
  • Copper tube/aluminum fin coil
  • Factory-installed liquid line filter dryer
  • 850 RPM condenser fan motor
  • Ground lug connection
  • Contactor with lug connections
  • Brass liquid and suction service valves with sweat connections
  • High-quality compressor sound blanket
  • Service valves with sweat connections and easy-access gauge ports
  • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds

 

AEPF (indoor) Air HandlerFeatures:

  • ARI Certified; ETL Listed
  • Design for refrigerants R-410A or R-22
  • Multi-Positional (vertical mount for closet or horizontal mount for attic)
  • Vaiable speed motor
  • Copper tube/aluminum fin coil
  • Transformer and blower time-delay on all units
  • Check flowrater expansion device for cooling-only and heat pump applications

GSX13/ AEPF Cabinet Features:

  • Unique Goodman® sound control top design (GSX13)
  • Steel louver coil guard (GSX13)
  • Heavy-gauge galvanized-steel cabinet (GSX13)
  • Steel louver coil guard for maximum protection (GSX13)
  • Attractive Architectural Gray powder-paintfinish with 500-hour salt-spray approval (GSX13)
  • When properly anchored, meets Florida Building Code unit integrity requirements for hurricane-type winds (GSX13)
  • Rust-resistant, fully insulated steel cabinet (AEPF)
  • Baked-on powder-paint finish (AEPF)
  • Rust-resistant coated screws (AEPF)
  • Galvanized, stucco-embossed finish (AEPF)
  • Attractive Architectural Gray painted front panels (AEPF)
  • Built-in filter rack for 1” filter (filter not included) (AEPF)
  • Power supply entry at top; low-voltage entry on left side and top (AEPF)

Notice:

This unit should be installed by a qualified licensed HVAC technician. The products we sell on our site are intended by the manufacturers to be installed by professional heating and air conditioning contractors. They are available to you the homeowners as a means of saving a substantial amount of money. We know the advantages of self-installation, as well as any disadvantages, and it’s your decision to purchase from us and install on your own.

You may also be interested in the following product(s)

Ruud 3 Ton 14 SEER R410A Air Conditioner Split System With GE ECM X13 Motor

Ruud 3 Ton 14 SEER R410A Air Conditioner Split System With GE ECM X13 Motor
$1,849.00

Ruud 2 Ton 14 SEER R410A Air Conditioner Split System With GE X13 ECM Motor Plus 5kw Heater Included

Ruud 2 Ton 14 SEER R410A Air Conditioner Split System With GE X13 ECM Motor Plus 5kw Heater Included
$1,685.00
   

Additional Information

SKU GSX130361A/AEPF313716
Stock Status N/A
Condition new
Manufacturer Goodman
Tax Rebate Qualifies
Outdoor Specs

GSX130361A

Capacity 3 Ton
Cooling Capacity 36,000 Btu
Efficiency 14 Seer
EER 11
Refrigerant R410A
System Stage One Stage
Compressor Type Copeland Scroll
Outdoor Voltage 208-230 1 Phase
Req. Breaker Size 30 Amps
Min/Max Volts 197/253
Suction Line Size 7/8"
Liquid Line Size 3/8"
Sound Level 74 DB
Dimensions 29"W x 29"D x 32 1/4"H
Shipping Weight 197 Lbs
Indoor Unit Specs

AEPF313716

Model Series AEPF
Air Handler Motor Variable Speed
Cooling Capacity 2.5 - 3 Ton
Blower Cooling Capacity 30,000 - 36,000 Btu
Configuration Multi-position
Suction Line Size 3/4"
Liquid Line Size 3/8"
CFM - High, Medium, Low 1,200/ 1000
Electrical Heat Capacity 5,8,10 15 Kw
Indoor Voltage 208-230 1 Phase
Max Breaker 15 amps
Min/Max Volts 197/253
Plenum Dimensions Supply-17 1/2 W x 11 D ~ Return-17 1/8 W x 17 15/16 D
Air Filter Dimensions 22 W x 24 D x 1 H
Unit Dimensions 22 W x 24 D x 53 1/4 H
Shipping Weight 176 Lbs
FAQ

Is this unit under warranty?

Under the terms of the manufacturer's warranty and to comply with federal refrigerant handling laws, it is required that the system be checked, started up and signed-off on by a licensed ac contractor prior to use. Failure to comply with this provision will void all factory warranties. Keep a copy of the installation ticket for your records. Please consult your local licensed and E.P.A. certified installer for any advice on the proper selection for your application before you place your order.


How do I contact a contractor to make the equipment installation?

Please use the Find a contractor system on this website to locate a professional Contractor near you. Please note that the Contractors listed on the AC Unit Direct Locator system are independent contractors and are not owned by, employed by, operated by, or authorized by acunitdirect.com.

For more information please see our FAQ's.

Total Weight 373.0000
Free Shipping Yes
Documents

What is SEER (Seasonal Energy Efficiency Ratio)?

SEER is the measure of efficiency by which the cooling process of air conditioners and heat pumps is rated. The higher the SEER number, the greater the efficiency–and therefore the greater the energy savings. Today, U.S. regulatory agencies require all new products to have a 13.0 SEER rating or better. Bryant's full line of air conditioners offers SEER ratings of up to 20.


How a Central Air AC Works?

A traditional home comfort system has two parts: an indoor unit, such as a furnace or air handler, and an outdoor unit. An air conditioner is the outdoor unit that cools air and sends it to the indoor unit for circulation through your home. Indoor and outdoor units are designed to work together. When the air conditioner is properly matched with a furnace or air handler, you get maximum efficiency and longer system life. Air conditioning and cooling efficiency is measured using a Seasonal Energy Efficiency Ratio (SEER). A higher SEER means higher energy efficiency. The latest standard for SEER is 13 (beginning January 2006).


How a Central AC Works

 

Benefits

* Indoor comfort during warm weather - Central air conditioning helps keep your home cool and reduces humidity levels.

 

* As your central air conditioning system draws air out of various rooms in the house through return air ducts, the air is pulled through an air filter, which removes airborne particles such as dust and lint. Sophisticated filters may remove microscopic pollutants, as well. The filtered air is then routed to air supply duct work that carries it back to rooms.

 

* Because the compressor bearing unit is located outside the home, the indoor noise level from its operation is much lower than that of a free-standing air conditioning unit.